Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

iDRAC 8/7 v2.70.70.70 RACADM CLI Guide

PDF

storage

Table 1. Details of storageThe following table provides the details of storage subcommand:
Description Allows you to run the commands to control storage arrays.

To run this subcommand for configuring the storage properties, you must have the server control permission.

NOTE: : You can also run the command using raid in place of the storage command.

Synopsis

Inventory

  • To view the help details for get command, run the following command:
    racadm storage help get
  • To generate and view information about the inventory of storage root node, run the following command:
    racadm storage get status
  • To generate and view information about the inventory of controllers, run the following command:
    racadm storage get controllers -o
    racadm storage get controllers -o -p <property names separated by comma>
  • To get the list of controllers, run the following command:
    racadm storage get controllers
  • To get the properties of PCIeSSD controller, run the following command:
    racadm storage get controllers:<PcieSSD controller FQDD>
  • To generate and view information about the inventory of batteries, run the following command:
    racadm storage get batteries -o
    racadm storage get batteries --refkey <controller FQDD's separated by comma> 
    racadm storage get batteries --refkey <controller FQDD's separated by comma> -o
    racadm storage get batteries --refkey <controller FQDD's separated by comma> -o -p <property names separated by comma>
  • To generate and view information about the inventory of virtual disks, run the following command:
    racadm storage get vdisks
    racadm storage get vdisks --refkey <controller FQDDs separated by comma> 
    racadm storage get vdisks --refkey <controller FQDDs separated by comma> -o
    racadm storage get vdisks --refkey <controller FQDDs separated by comma> -o -p <property names separated by comma>
  • To generate and view information about the inventory of enclosures, run the following command:
    racadm storage get enclosures -o
    racadm storage get enclosures --refkey <connector FQDDs separated by comma>
    racadm storage get enclosures --refkey <connector FQDDs separated by comma> -o -p <property names separated by comma>
  • To get the list of enclosures, run the following command:
    racadm storage get enclosures
  • To get the properties of the PCIeSSD enclosure, run the following command:
    racadm storage get enclosures:<PCIeSSD enclosure FQDD>
  • To generate and view information about the inventory of physical disk drives, run the following command:
    racadm storage get pdisks
    racadm storage get pdisks -o
    racadm storage get pdisks -o -p <property names separated by comma>
    racadm storage get pdisks --refkey <enclosure/Backplanes FQDDs separated by comma>
    racadm storage get pdisks --refkey <enclosure/Backplanes FQDDs separated by comma> -o
    racadm storage get pdisks --refkey <enclosure/Backplanes FQDDs separated by comma> -o -p <property names separated by comma>
  • To get the list of physical disks, run the following command:
    racadm storage get pdisks
  • To get the properties of PCIeSSD physical disk, run the following command:
    racadm storage get pdisks:<PCIeSSD FQDD>
  • To generate and view information about the inventory of fans, run the following command:
    racadm storage get fans --refkey <enclosure FQDDs separated by comma>
    racadm storage get fans --refkey <enclosure FQDDs separated by comma > -o 
    racadm storage get fans --refkey <enclosure FQDDs separated by comma> -o -p <property names separated by comma> 
  • To generate and view information about the inventory of EMMs, run the following command:
    racadm storage get emms -refkey <enclosure FQDDs separated by comma>
    racadm storage get emms --refkey <enclosure FQDDs separated by comma> -o
    racadm storage get emms --refkey <enclosure FQDDs separated by comma> -o -p <property names separated by comma> 
  • To generate and view information about the inventory of PSU, run the following command:
    racadm storage get psus -refkey <enclosure FQDDs separated by comma>
    racadm storage get psus --refkey <enclosure FQDDs separated by comma> -o
    racadm storage get psus --refkey <enclosure FQDDs separated by comma> -o -p <property names separated by comma> 

Configuration

  • To view the help details for a configuration command, run the following command:
    racadm storage help <command>
    where command can take below values
    converttoraid, converttononraid, controllers, clearconfig, createsecuritykey, createvd, deletesecuritykey, deletevd, encryptvd, enclosures, emms, fans, hotspare, importconfig, ccheck, secureerase, preparetoremove, blink, unblink, cancelcheck, init, modifysecuritykey, psus, pdisks, resetconfig, tempprobes, vdisks, cancelbgi, 
    replacephysicaldisk, setbootvd, forceonline, forceoffline, unlock and patrolread.
  • To create, delete, and secure the virtual disks. To start or stop the consistency check on the specified virtual disk, run the following command:
    racadm storage createvd:<Controller FQDD> -rl {r0|r1|r5|r6|r10|r50|r60}[-wp {wt|wb|wbf}] [-rp {nra|ra|ara}] [-ss {1k|2k|4k|8k|16k|32k|64k|128k|256k|512k|1M|2M|4M|8M|16M}]-pdkey:<comma separated PD FQDD> [-dcp {enabled|disabled|default}] [-name <VD name>] [-size <VD size>{b|k|m|g|t}] [-T10PIEnable]

    NOTE: : T10PI is not supported on PERC 9 and PERC 10.

    racadm storage init:<VD FQDD> -speed {fast|full} 
    racadm storage deletevd:<VD FQDD>
    racadm storage encryptvd:<VD FQDD>
    racadm storage createsecuritykey:<Controller FQDD> -key <Key id> -xxx <passphrase>

    NOTE: : createsecuritykey command is not supported on H3xx PERC controllers.

    racadm storage modifysecuritykey:<Controller FQDD> -key <Key id>-xxx <old passphrase> -xxx <new passphrase>
    racadm storage deletesecuritykey:<Controller FQDD>
    racadm storage ccheck:<vdisk fqdd>
    racadm storage cancelcheck:<vdisk fqdd>
  • To convert the physical disk drives and assign or delete a hotspare. To scan physical disks connected to a controller and detect problem, run the following command:
    racadm storage converttononraid:<PD FQDD>

    NOTE: : Convert to RAID and non-RAID is not supported on PERC 10 and BOSS controllers.

    racadm storage converttoraid:<PD FQDD>
    racadm storage hotspare:<Physical Disk FQDD> -assign yes -type dhs -vdkey: <FQDD of VD>
    racadm storage hotspare:<Physical Disk FQDD> -assign yes –type ghs
    racadm storage hotspare:<Physical Disk FQDD> -assign no
    racadm storage patrolread:<controller FQDD> -state start|stop
    racadm raid cancelbgi:<VD FQDD>
    racadm raid replacephysicaldisk:<PD FQDD> -dstpd <PD FQDD>

    NOTE: : replacephysicaldisk method is not supported on non-redundant RAID volumes.

    racadm raid setbootvd:<Controller FQDD> -vd <VD FQDD>
    racadm raid forceonline:<PD FQDD>
    racadm raid forceoffline:<PD FQDD>
    racadm storage unlock:<Controller FQDD> -key <Key id> -passwd <passphrase>

    NOTE: : If the –assign option is no, you cannot add other options. If the –assign option is yes and if the -type option is not present, the global hotspare (ghs) is created by default.

  • To reset, clear, and import the storage configuration to the controller, run the following command:
    racadm storage importconfig:<Controller FQDD>
    racadm storage resetconfig:<Controller FQDD>
    racadm storage clearconfig:<Controller FQDD>
  • To start or stop a blink or identify operation on the specified or PCIeSSD device, run the following command:
    racadm storage blink:<FQDD>
    racadm storage blink:<PCIeSSD FQDD>
    racadm storage unblink:<FQDD>
    racadm storage unblink:<PCIeSSD FQDD>

    NOTE: : The Start or Stop a Blink feature is not supported for HHHL PCIe SSD devices.

  • To prepare the PCIeSSD drive for removal, run the following command:
    racadm storage preparetoremove <PCIeSSD FQDD>

    NOTE: : The preparetoremove task is not supported for HHHL PCIe SSD devices.

    NOTE: : Ensure that the ISM is installed and running to perform the preparetoremove operation.

  • To perform a secure erase operation on PCIeSSD device, run the following command:
    racadm storage secureerase:<PCIeSSD FQDD>

    NOTE: : securerase is now supported on SED drives along with PCIe SSD devices.

Input
  • -o—Specifies the optimized version.
  • -p—Specifies the property name.
  • --refkey—Specifies the controller or enclosure FQDDs.
  • -rl—Sets the storage level.
    • r0—storage 0-Striping
    • r1—storage 1-Mirroring
    • r5—storage 5-Striping with Parity
    • r6—storage 6-Striping with Extra Parity
    • r10—storage 10-Spanned Striping with Mirroring
    • r50—storage 50-Spanned Striping with Parity
    • r60—storage 60-Spanned Striping with Extra Parity
  • -wp{wt|wb|wbf}—Sets the write policy to Write Through, Write Back, or Write Back Force
  • -rp {nra|ra|ara}—Sets the read policy to No Read Ahead, Read Ahead, Adaptive Read Ahead
  • -ss—Specifies the stripe size to use.
  • -pdkey:<PD FQDD list>—Specifies the physical disk drive to use in the virtual disk.
  • -dcp—Sets the Disk Cache Policy in the Virtual Disk.
    • enabled—Allows the virtual disk to use the cache.
    • disabled—Does not allow the virtual disk to use the cache.
    • default—Uses the default cache policy. For SAS drives, use the disabled option and for SATA drives, use the enabled option by default.
  • -name <VD name>—Specifies the name of the virtual disk.
  • -size <VD size>—Specifies the size of each virtual disk.
    • b—Specifies the size in bytes
    • k—Specifies the size in kilobytes
    • m—Specifies the size in megabytes
    • g—Specifies the size in gigabytes
    • t—Specifies the size in terabytes
  • -sc—Number of spans in a virtual disk (required for multi-span RAID level).

    NOTE: :

    • For PERC9, if the value of controller.SupportRAID10UnevenSpans is supported, you can enter only 0 for this option while creating RAID level 10. The created RAID10 virtual disk displays the spandepth as 1 (default).
    • For other controllers:
      • The default value for multi-span RAID levels is 2 and for basic RAID level is 1.
      • For hybrid RAID levels such as RAID10, RAID50, and RAID60, this option is mandatory.
      • The value for-sc option can be 0 only for RAID10.

  • -T10PIEnable—Creates a virtual disk with protection information.
  • -key <Key id>—Specifies the key id.
  • -passwd <passphrase>—Specifies the passphrase.
  • -newpasswd <passphrase>—Specifies the new passphrase.
  • -assign {yes | no}—Assigns or unassigns the disk as a hotspare.
  • -type { ghs | dhs}—Assigns a global or dedicated hotspare.
  • -vdkey:<VD FQDD>—Assigns the dedicated hotspare to the specified virtual disk. This option is required for dedicated hotspare.
  • -state <start|stop>—start value starts a patrol read operation. stop value stops a running patrol read operation.

    NOTE: : To start the operation, the Controller.PatrolReadMode must be in Manual mode.

  • -dstpd-replaces a physical disk in virtual disk configuration.
  • -vd-virtual disk fqdd to make it as a bootable drive.
  • -speed—Specifies the initialization of the Virtual disk.

    • fast—Performs fast initialization.

    • full—Performs slow initialization.

  • blink: <FQDD> or unblink: <FQDD>—<FQDD> can be physical disk drives, virtual disks, or PCIeSSD.
  • <PCIeSSD FQDD>—Specifies the PCIeSSD FQDD.
  • <PCIeSSD controller|enclosure FQDD>—Specifies the PCIeSSD controller or enclosure FQDD.
  • preparetoremove—Specifies the PCIeSSD drive to prepare for removal.

    NOTE: : Ensure that ISM is installed and running to perform the preparetoremove operation.

  • secureerase—Specifies the PCIeSSD drive to perform the secure erase operation.

Example

Inventory

  • To view the help details for get command, run the following command:
    racadm>>storage help get
    racadm storage help get
    Storage monitoring and inventory of hardware RAID connected to the system.
    
    Usage :
    racadm storage get status
    racadm storage help <Object type I/II>
    racadm storage get <Object type I>
    racadm storage get <Object type I> -current
    racadm storage get <Object type I> -pending
    racadm storage get <Object type I> -o
    racadm storage get <Object type I> -o -p <property names separated by comma>
    racadm storage get <Object type I>:<FQDD's of Object type I separated by comma> -p
    <property names separated by comma>
    racadm storage get <Object type I>:<FQDD's of Object type I separated by comma>
    racadm storage get <Object type II> --refkey <reference keys separated by comma>
    racadm storage get <Object type II> --refkey <reference keys separated by comma> -o
    racadm storage get <Object type II> --refkey <reference keys separated by comma> -o
    -p <property names separated by comma>
    --------------------------------------------------------------------------------
    
    Valid Options:
    Object type I      : controllers, batteries, vdisks, pdisks, fans, emms, tempprobes, psus, enclosures.
    Object type II     : batteries, vdisks, pdisks, fans, emms, psus, tempprobes, enclosures.
    -current <optional>: Displays only the current Raid objects from storage.If -pending not mentioned it will consider as the default option
    -pending           : Displays only the Pending Raid Objects from Storage.
    -o                 : Displays all the properties of the selected Key or Object.
    -p                 : Displays the property names with filter.
    FQDD's             : Displays all the properties of the FQDD's Key.
    --refkey           : Displays all the reference key of Object type.
    help               : Displays each object type help.
    NOTE: Maximum Property names can be specified in -p option is = 10.
    NOTE: Maximum FQDD's or refkey can be specified is = 3.
    --------------------------------------------------------------------------------
    
    Usage Examples :
    racadm storage get controllers
    racadm storage get psus
    racadm storage get controllers -o
    racadm storage get controllers -o -current
    racadm storage get controllers -o -pending
    racadm storage get enclosures -o
    racadm storage get controllers -o -p name,status
    racadm storage get vdisks -o -p layout,status
    racadm storage get controllers:RAID.INTEGRATED.0
    racadm storage get emms:EMM.Slot.0:ENCLOSURE.EXTERNAL.0-0:RAID.INTEGRATED.0
    racadm storage get controllers:RAID.INTEGRATED.0 -p status
    racadm storage get emms:EMM.Slot.0:ENCLOSURE.EXTERNAL.0-0:RAID.INTEGRATED.0 -p status
    racadm storage get batteries --refkey RAID.INTEGRATED.0
    racadm storage get pdisks --refkey ENCLOSURE.EXTERNAL.0-0:RAID.INTEGRATED.0
    racadm storage get batteries --refkey RAID.INTEGRATED.0 -o -p status,state,name
    racadm storage get fans --refkey RAID.INTEGRATED.0 -o -p status,speed,name
    
  • To generate and view information about the inventory of controllers, virtual disks, storage enclosures, and physical drives.
    • To generate and view information about the inventory of storage root node.
      This command retrieves the status of the inventory for storage root node.
      racadm storage get status
      raid Root Node Status : Ok
    • To generate and view information about the inventory of controllers connected to the server. 
      racadm storage get controllers
      RAID.Integrated.1-1
      The following command is an optimized version and displays the full controller objects along with their keys:
      racadm storage get controllers -o
      RAID.Integrated.1-1
         Status                           = Ok
         DeviceDescription                = Integrated RAID Controller 1
         RollupStatus                     = Ok
         Name                             = PERC H730P Mini (Embedded)
         FirmwareVersion                  = 25.2.1.0025
         DriverVersion                    = Information Not Available
         RebuildRate                      = 45
         BgiRate                          = 13
         CheckConsistencyRate             = 18
         ReconstructRate                  = 12
         PatrolReadRate                   = 21
         PatrolReadMode                   = Disabled
         PatrolReadState                  = Stopped
         CheckConsistencyMode             = Normal
         LoadBalanceSetting               = Disabled
         CopybackMode                     = OFF
         PreservedCache                   = Not Present
         CacheMemorySize                  = 2048 MB
         PersistHotspare                  = Disabled
         SpindownUnconfiguredDrives       = Disabled
         SpindownHotspare                 = Disabled
         Timeintervalforspindown          = 30 (Minutes)
         SecurityStatus                   = Security Key Assigned
         EncryptionMode                   = Supported with LKM
         SasAddress                       = 0x5B8CA3A0F3073700
         PciDeviceId                      = 0x5d
         PciSubdeviceId                   = 0x1f47
         PciVendorId                      = 0x1000
         PciSubvendorId                   = 0x1028
         PciBus                           = 0x3
         PciDevice                        = 0x0
         PciFunction                      = 0x0
         BusWidth                         = Unknown
         SlotLength                       = Unknown
         SlotType                         = Unknown
         MaxCapableSpeed                  = 12.0 Gb/s
         LearnMode                        = Not supported
         T10PICapability                  = Capable
         SupportRAID10UnevenSpans         = Supported
         SupportEnhancedAutoForeignImport = Supported
         EnhancedAutoImportForeignConfig  = Enabled
         SupportControllerBootMode        = Supported
         ControllerBootMode               = Continue Boot On Error
         RealtimeConfigurationCapability  = Capable
         CurrentControllerMode            = RAID
         BootVD                           = Disk.Virtual.0:RAID.Integrated.1-1
      The following command displays the filtered property values for all returned controller objects:
      racadm storage get controllers -o -p Name
      RAID.Integrated.1-1
      Name = PERC H710P Adapter (Embedded)

      The following examples show the pending operation when used with storage get <object> commands:

      To list storage objects without displaying the properties:
      • This operation displays vdisk, which has pending operation:
        racadm storage get vdisks -pending
        DISK.Virtual.267386880:RAID.Slot.5-1  
      • This operation displays controllers, which have pending operations:
        racadm storage get controllers -pending 
        RAID.Integrated.1-1
      • This operation displays pdisk, which has pending operation:
        racadm storage get pdisks -pending 
        Disk.Bay.20:Enclosure.Internal.0-1:RAID.Integrated.1-1
      • This operation displays enclosures, which have pending operations:
        racadm storage get enclosures -pending 
        Enclosure.Internal.0-1:RAID.Integrated.1-1
        Changing the attribute by using racadm set storage or storage configuration command displays the storage object in the -pending command output. If there are no pending objects, the following error message is displayed:
        racadm storage get pdisks -pending 
        ERROR: STOR0103 : No physical disks are displayed.
        Check if the server has power, physical disks are available, and physical disks are connected to the enclosure or backplane.

      The following examples show the pending operation while listing the properties:

      By default, if there is no change in properties, the -pending command displays the current value. If the property has any pending objects, the -pending command displays the pending value.
      • This operation displays the current state of pdisk, which is in Ready state:
        /admin1-> racadm storage get pdisks -o -p state
        Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1
           State                            = Ready
      • This operation displays state of a pdisk on which createvd operation is pending:
        /admin1-> racadm storage get pdisks -o -p state -pending
        Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1
      The following command displays the output for PowerEdge FD332 support and full controller objects along with their keys:
      racadm storage get controllers -o
      RAID.Modular.3-1
         Status                           = Ok
         DeviceDescription                = Integrated RAID Controller 1 in Front Chassis Slot 3
         RollupStatus                     = Ok
         Name                             = Slot 3,PERC FD33xS(Controller 1)
         FirmwareVersion                  = 25.2.2-0001
         RebuildRate                      = 55
         BgiRate                          = 55
         CheckConsistencyRate             = 55
         ReconstructRate                  = 55
         PatrolReadRate                   = 50
         PatrolReadMode                   = Manual
         PatrolReadState                  = Stopped
         CheckConsistencyMode             = Normal
         LoadBalanceSetting               = Disabled
         CopybackMode                     = OFF
         PreservedCache                   = Not Present
         CacheMemorySize                  = 2048 MB
         PersistHotspare                  = Disabled
         SpindownUnconfiguredDrives       = Disabled
         SpindownHotspare                 = Disabled
         Timeintervalforspindown          = 30 (Minutes)
         SecurityStatus                   = Encryption Capable
         EncryptionMode                   = None
         SasAddress                       = 0x5B083FE0E3EF5A00
         PciDeviceId                      = 0x5d
         PciSubdeviceId                   = 0x1f4d
         PciVendorId                      = 0x1000
         PciSubvendorId                   = 0x1028
         PciBus                           = 0x7
         PciDevice                        = 0x0
         PciFunction                      = 0x0
         BusWidth                         = 8x or x8
         SlotLength                       = Other
         SlotType                         = PCI Express Gen3
         MaxCapableSpeed                  = 12.0 Gb/s
         LearnMode                        = Not supported
         T10PICapability                  = Capable
         SupportRAID10UnevenSpans         = Supported
         SupportEnhancedAutoForeignImport = Supported
         EnhancedAutoImportForeignConfig  = Disabled
         SupportControllerBootMode        = Supported
         ControllerBootMode               = Continue Boot On Error
         RealtimeConfigurationCapability  = Capable
         CurrentControllerMode            = RAID
         BootVD                           = Disk.Virtual.0:RAID.Integrated.1-1
      
      The following command displays the output for software RAID and full controller objects along with their keys:
      racadm storage get controllers -o
      RAID.Embedded.1-1
         Status                           = Unknown
         DeviceDescription                = Embedded RAID Controller 1
         RollupStatus                     = Unknown
         Name                             = PERC S130 Controller (PCI Slot 0)
         PciSlot                          = 0
         FirmwareVersion                  = 4.0.0-0037
         DriverVersion                    = Information Not Available
         RebuildRate                      = 0
         BgiRate                          = 0
         CheckConsistencyRate             = 0
         ReconstructRate                  = 0
         PatrolReadRate                   = 0
         PatrolReadMode                   = Not supported
         PatrolReadState                  = Unknown
         CheckConsistencyMode             = Not supported
         LoadBalanceSetting               = Not Supported
         CopybackMode                     = Not supported
         PreservedCache                   = Not Present
         CacheMemorySize                  = 0 MB
         PersistHotspare                  = Disabled
         SpindownUnconfiguredDrives       = Disabled
         SpindownHotspare                 = Disabled
         Timeintervalforspindown          = 0 (Minutes)
         SecurityStatus                   = Unknown
         EncryptionMode                   = None
         SasAddress                       = Not applicable
         PciDeviceId                      = 0x8d66
         PciSubdeviceId                   = 0x61b
         PciVendorId                      = 0x8086
         PciSubvendorId                   = 0x1028
         PciBus                           = 0x0
         PciDevice                        = 0x0
         PciFunction                      = 0x0
         BusWidth                         = Unknown
         SlotLength                       = Unknown
         SlotType                         = Unknown
         MaxCapableSpeed                  = 6.0 Gb/s
         LearnMode                        = Not supported
         T10PICapability                  = Not Capable
         SupportRAID10UnevenSpans         = Not Supported
         SupportEnhancedAutoForeignImport = Not Supported
         EnhancedAutoImportForeignConfig  = Unknown
         SupportControllerBootMode        = Not Supported
         RealtimeConfigurationCapability  = Incapable
         CurrentControllerMode            = Not Supported
         BootVD                           = Disk.Virtual.0:RAID.Integrated.1-1
      
    • To generate and view information about the inventory of batteries connected to the controller, run the following command:
      racadm storage get batteries
      The following command is an optimized version and displays the batteries along with their keys:
      racadm storage get batteries -o
      Battery.Integrated.1:RAID.Integrated.1-1 
      Name                             = Battery
      DeviceDescription                = Battery on Integrated raid Controller 1
      Status                           = Ok
      State                            = Ready
      The following command displays the filtered property values for all battery objects:
      racadm storage get batteries -o -p Name
      Battery.Integrated.1:RAID.Integrated.1-1
      Name  = Battery
      The following command displays all battery keys connected to the controllers:
      racadm storage get batteries --refkey RAID.Integrated.1-1
      Battery.Integrated.1:RAID.Integrated.1-1
      The following command is an optimized and filtered version:
      racadm storage get batteries --refkey RAID.Integrated.1-1 -o -p Name
      Battery.Integrated.1:RAID.Integrated.1-1
      Name                             = Battery
    • To generate and view information about the inventory of virtual disks connected to the controller., run the following command:
      racadm storage get vdisks 
      Disk.Virtual.0:RAID.Integrated.1-1
      The following command displays all virtual disk keys connected to the controllers:
      racadm storage get vdisks --refkey RAID.Integrated.1-1
      Disk.Virtual.0:RAID.Integrated.1-1
      The following command is an optimized and filtered version:
      racadm storage get vdisks -o -p DeviceDescription,OperationalState
      Disk.Virtual.0:RAID.Integrated.1-1
      DeviceDescription        = Virtual Disk 0 on Integrated raid Controller 1
      OperationalState         = Not applicable
    • Table 2. To generate and view information about the inventory of virtual disksTo generate and view information about the inventory of virtual disks, run the following command:
      racadm storage get vdisks -o
      Disk.Virtual.2:RAID.Integrated.1-1
      Status
      Ok
      
      DeviceDescription 
      Virtual Disk 2 on Integrated RAID Controller 1
      
      Name
      OS
      
      RollupStatus
      Ok
      
      State
      Online
      OperationalState
      Not applicable
      Layout
      Raid-0
      
      Size 
      278.88 GB
      
      SpanDepth
      1
      AvailableProtocols
      SAS
      MediaType
      HDD
      ReadPolicy 
      Read Ahead
      WritePolicy
      Write Back
      StripeSize
      64K
      DiskCachePolicy
      Default
      BadBlocksFound
      NO
      Secured
      NO
      RemainingRedundancy
      0
      
      EnhancedCache
      Not Applicable
      
      T10PIStatus
      Disabled
      BlockSizeInBytes
      512
    • Table 3. To generate and view information about the inventory of storage enclosuresTo generate and view information about the inventory of storage enclosures connected to the connector.

      This command displays all enclosure objects for the connector FQDD.

      racadm storage get enclosures -o
      Enclosure.Internal.0-1:RAID.Integrated.1-1
      
      Status Ok
      State Ready
      DeviceDescription Backplane 1 on Connector 0 of Integrated RAID Controller 1
      RollupStatus Ok
      Name BP13G+EXP 0:1
      BayId 1
      FirmwareVersion 0.23
      SasAddress 0x500056B31234ABFD
      SlotCount 24
      The following command displays all enclosure keys connected to the connectors:
      racadm storage get enclosures --refkey RAID.Integrated.1-1
      Enclosure.Internal.0-1:RAID.Integrated.1-1
      The following command is an optimized and filtered version:
      racadm storage get enclosures --refkey RAID.Integrated.1-1 -o -p Name
      Enclosure.Internal.0-1:RAID.Integrated.1-1
      Name = BP12G+EXP 0:1
    • To generate and view information about the inventory of physical disk drives connected to the enclosure or backplanes, run the following command:
      racadm storage get pdisks
      Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1
      The following command is an optimized version and displays the full controller physical disks along with their keys:
      racadm storage get pdisks -o
      racadm storage get pdisks
      Disk.Bay.23:Enclosure.Internal.0-1:RAID.Integrated.1-1
         Status                           = Ok
         DeviceDescription                = Disk 23 in Backplane 1 of Integrated RAID Controller 1
         RollupStatus                     = Ok
         Name                             = Physical Disk 0:1:23
         State                            = Online
         OperationState                   = Not Applicable
         PowerStatus                      = Spun-Up
         Size                             = 558.38 GB
         FailurePredicted                 = NO
         RemainingRatedWriteEndurance     = Not Applicable
         SecurityStatus                   = Not Capable
         BusProtocol                      = SAS
         MediaType                        = HDD
         UsedRaidDiskSpace                = 136.13 GB
         AvailableRaidDiskSpace           = 0.00 GB
         Hotspare                         = NO
         Manufacturer                     = SEAGATE
         ProductId                        = ST9600204SS
         Revision                         = FM08
         SerialNumber                     = 6WN09DXN
         PartNumber                       = CN07T0DW7262211M01Y6A00
         NegotiatedSpeed                  = 6.0 Gb/s
         ManufacturedDay                  = 2
         ManufacturedWeek                 = 4
         ManufacturedYear                 = 2011
         SasAddress                       = 0x5000C5003324E93D
         FormFactor                       = 2.5 Inch
         RaidNominalMediumRotationRate    = 10000
         T10PICapability                  = Not Capable
         BlockSizeInBytes                 = 512
         MaxCapableSpeed                  = 6 Gb/s
      
      The following command displays the filtered property values for all returned controller objects:
      racadm storage get pdisks -o -p State
      Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1
      State = Online
      The following command displays all physical disk drive keys connected to the enclosures:
      racadm storage get pdisks --refkey RAID.Integrated.1-1
      Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1
      The following command is an optimized version and displays all disk objects for the enclosure FQDD:
      racadm storage get pdisks --refkey Enclosure.Internal.0-1:RAID.Integrated.1-1 -o
      racadm storage get pdisks -o
      Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1
      Status                           = Ok
      DeviceDescription                = Disk 0 in Backplane 1 of Integrated raid Controller 1
      RollupStatus                     = Ok
      Name                             = Physical Disk 0:1:0
      State                            = Online
      OperationState                   = Not Applicable
      PowerStatus                      = Spun-Up
      Size                             = 278.88 GB
      FailurePredicted                 = NO
      RemainingRatedWriteEndurance     = Not Applicable
      SecurityStatus                   = Not Capable
      BusProtocol                      = SAS
      MediaType                        = HDD
      UsedraidDiskSpace                = 278.88 GB
      AvailableraidDiskSpace           = 0.00 GB
      Hotspare                         = NO
      Manufacturer                     = SEAGATE
      ProductId                        = ST9300605SS
      Revision                         = CS05
      SerialNumber                     = 6XP40SA9
      PartNumber                       = CN0745GC7262228706R7A00
      NegotiatedSpeed                  = 6.0 Gb/s
      ManufacturedDay                  = 4
      ManufacturedWeek                 = 32
      ManufacturedYear                 = 2012
      SasAddress                       = 0x5000C5005952386D
      FormFactor                       = 2.5 Inch
      raidNominalMediumRotationRate    = 10000
      T10PICapability                  = Not Capable
      BlockSizeInBytes                 = 512
      MaxCapableSpeed                  = 6 Gb/s
      ForeignKeyIdentifier             = dellkey1
      The following command is an optimized and filtered version:
      racadm storage get pdisks --refkey Enclosure.Internal.0-1:RAID.Integrated.1-1 -o -p State
      Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1
      State = Online
    • To generate and view information about the inventory of fans connected to the enclosure.
      The following command displays all the fan keys connected to the enclosures:
      racadm storage get fans --refkey <enclosure FQDDs separated
      by comma>
      The following command displays all the fan objects for the enclosure FQDD:
      racadm storage get fans --refkey <enclosure FQDDs separated
      by comma > -o 
      racadm storage get fans --refkey <enclosure FQDDs separated
      by comma> -o -p <property names separated by comma> 
    • To generate and view information about the inventory of EMMs connected to the enclosure.
      The following command returns all the EMM keys connected to the enclosures:
      racadm storage get emms -refkey <enclosure FQDDs separated
      by commaenclosure FQDDs separated
      by comma>
      The following command is an optimized version and displays all the EMM objects for the enclosure FQDD:
      racadm storage get emms --refkey <enclosure FQDDs separated
      by comma> -o
      The following command is an optimized and filtered version:
      racadm storage get emms --refkey <enclosure FQDDs separated
      by comma > -o -p <property names separated by comma>
    • To generate and view information about the inventory of PSU connected to the enclosure.
      The following command displays all the PSUs connected to the enclosures:
      racadm storage get psus --refkey <enclosure FQDD's separated
      by comma>
      The following command is an optimized version and displays all the PSUs objects for the enclosure FQDD:
      racadm storage get psus --refkey <enclosure FQDD's separated
      by comma > -o
      The following command is an optimized and filtered version:
      racadm storage get psus --refkey <enclosure FQDD's separated
      by comma> -o -p <property names separated by comma>
  • To get the list of enclosures and properties of the PCIeSSD enclosure.
    • The following command provides the list of enclosures:
      racadm storage get enclosures
      Enclosure.Internal.0-1:RAID.Integrated.1-1\
      Enclosure.Internal.0-1:PCIeExtender.Slot.3
    • The following command provides the properties of the specified PCIeSSD enclosure:
      racadm storage get enclosures:Enclosure.Internal.0-1:PCIeExtender.Slot.3
      Enclosure.Internal.0-1:PCIeExtender.Slot.3
      RollupStatus = Ok
      DeviceDescription = Enclosure.Internal.0-1:PCIeExtender.Slot.3
      Name = PCIe SSD BP 1
      SlotCount = 4
      FirmwareVersion = 0.80
    • To get the list of physical disks and properties of the specified PCIeSSD physical disk.
      The following command provides the list of physical disks:
      racadm storage get pdisks
      Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1
      Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1
      Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1
      Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.1-1
      Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1
      Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1
      Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3
      Disk.Bay.6:Enclosure.Internal.0-1:PCIeExtender.Slot.3
      Disk.Bay.7:Enclosure.Internal.0-1:PCIeExtender.Slot.3
      Disk.Bay.9:Enclosure.Internal.0-1:PCIeExtender.Slot.3
      The following command provides the properties of the specified PCIeSSD physical disk:
      racadm storage get pdisks:Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3
      Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3
      Status = Ok
      DeviceDescription = PCIe Solid-State Drive in Slot 8 in Bay 1
      Name = Physical Device 8
      State = Ready
      Size = 745.21 GB
      BusProtocol = PCIe
      MediaType = SSD
      Model = SAMSUNG MZWEI800HAGM 000D3
      ProductId = a820
      SerialNumber = S1J1NYAD90019
      DeviceProtocol = NVMe1.0
      Manufacturer = SAMSUNG
      PCIeNegotiatedLinkWidth = x4
      PCIeCapableLinkWidth = x4
      MaxCapableSpeed = 8 GT/s
      NegotiatedSpeed = 8 GT/s
      FormFactor = 2.5 Inch
      Revision = IPM0ED35SAM SAMSUNG MZWEI800HAGM 000D3
      RemainingRatedWriteEndurance = 100 %
      FailurePredicted = NO
      
      To get the list of controllers and properties of the PCIeSSD controller.
      The following command provides the list of controllers:
      racadm storage get controllers
      RAID.Integrated.1-1
      PCIeExtender.Slot.3

      The following command provides the properties of the specified PCIeSSD controller:

      racadm storage get controllers:PCIeExtender.Slot.3
      PCIeExtender.Slot.3
      RollupStatus = Ok
      DeviceDescription = PCIe Extender in PCIe Slot 3
      Status = Ok
      Name = PCIeExtender 3 (PCI Slot 3)

    Configuration

  • To view the help details for a configuration command, run the following command:
    admin1-> racadm storage help createvd
    Storage configuration of hardware RAID connected to the system.
    
    Usage:
    racadm storage createvd:<Controller FQDD> -rl {r0|r1|r5|r6|r10|r50|r60}[-wp {wt|wb|wbf}] [-rp {nra|ra|ara}]
    [-ss {1k|2k|4k|8k|16k|32k|64k|128k|256k|512k|1M|2M|4M|8M|16M}]
    -pdkey:<comma separated PD FQDD> [-dcp {enabled|disabled|default}]
    [-name <VD name>] [-size <VD size>{b|k|m|g|t}] [-T10PIEnable]
    --------------------------------------------------------------------------------
    
    Options :
    -rl                    : Set the RAID Level
     r0                 : RAID 0  - Striping
     r1                 : RAID 1  - Mirroring
     r5                 : RAID 5  - Striping with Parity
     r6                 : RAID 6  - Striping with Extra Parity
     r10                : RAID 10 - Spanned Striping with Mirroring
     r50                : RAID 50 - Spanned Striping with Parity
     r60                : RAID 60 - Spanned Striping with Extra Parity
     -wp {wt | wb | wbf}    : Set the write policy to Write Through or Write Back or Write Back Force
     -rp {nra|ra|ara}       : Set the read policy to No Read Ahead, Read Ahead, Adaptive Read Ahead
     -ss                    : Specify the stripe size to use
     -pdkey:<PD FQDD list>  : The PDs to use in the VD.
     -dcp                   : Set the Disk Cache Policy in the VD
     enabled           : Enabled - Allow the disk to use it's cache
     disabled          : Disabled - Disallow the disk from using it's cache
     default           : Default - Use the default cache policy.
     SAS Drives  - Use Disabled by Default
     SATA Drives - Use Enabled by Default
     -name <VD name>        : The name to give the VD
     -size <VD size>        : The size of the VD
     b                : Specify the size in bytes
     k                : Specify the size in kilobytes
     m                : Specify the size in megabytes
     g                : Specify the size in gigabytes
     t                : Specify the size in terabytes
     -sc               : Spandepth: Number of spans in a virtual disk
    
    Note: 
     - This option is mandatory for hybrid raid level like RAID 10, RAID50 and RAID60.
     - The default value is one for basic RAID levels.
     - If RAID10 Uneven Span is Supported then for RAID10:
     -    -sc option will be optional.
     -    Will allow only 0 value for this option.
     -T10PIEnable                : To create a VD with PI
    --------------------------------------------------------------------------------
    Description :
    Create a VD.
    --------------------------------------------------------------------------------
    
    Examples :
    racadm storage createvd:RAID.Integrated.1-1 -rl r0 -pdkey:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1
  • To create, delete, and secure the virtual disks.
    • The following command creates a virtual disk:
      racadm storage createvd:RAID.Integrated.1-1 -rl r0 -pdkey:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1
    • The following command starts an initialization operation on a specified virtual disk:
      racadm storage init:Disk.Virtual.0:RAID.Integrated.1-1 -speed fast 
    • The following command deletes the specified virtual disk:
      racadm storage deletevd:Disk.Virtual.0:RAID.Integrated.1-1
    • The following command encrypts the specified virtual disk:
      racadm storage encryptvd:Disk.Virtual.0:RAID.Integrated.1-1

      NOTE: : Virtual disk must be created with SED.

    • The following command assigns security key for controller:
      racadm storage createsecuritykey:RAID.Integrated.1-1 -key <Key id> -xxx <passphrase>
    • The following command modifies security key for controller:
      racadm storage modifysecuritykey:RAID.Integrated.1-1 -key <Key id> -oldpasswd <oldpassphrase> -newpasswd <newpassphrase>
    • The following command deletes security key for controller:
      racadm storage deletesecuritykey:RAID.Integrated.1-1
  • To convert the physical disk drive and assign hotspare.
    • The following command converts the specified non-storage physical disk drive to a storage capable physical disk drive:
      racadm storage converttoraid:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 
    • The following command converts the specified physical disk drive to a non-storage physical disk drive:
      racadm storage converttononraid:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 
    • The following command assigns or unassigns a global or dedicated Hot spare:
      racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -assign no
      racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -assign yes -type ghs
      racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -assign yes -type dhs -vdkey:Disk.Virtual.0:RAID.Integrated.1-1
  • To reset, clear, and import the storage configuration to the controller.
    • The following command imports the current foreign configuration from the controller:
      racadm storage importconfig:RAID.Integrated.1-1
    • The following command deletes all virtual disks and un-assign hot spare from the associated controller:
      racadm storage resetconfig:RAID.Integrated.1-1
    • The following command clears the current foreign configuration from the controller:
      racadm storage clearconfig:RAID.Integrated.1-1

    NOTE: : After a resetconfig or clearconfig operation, the data cannot be reversed.

  • To blink or unblink the PCIeSSD device.
    • The following command blinks the specified PCIeSSD device:
      racadm storage blink:Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3
      STOR095 : Storage operation is successfully completed.
    • The following command unblinks the specified PCIeSSD device:
      racadm storage unblink:Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3
      STOR095 : Storage operation is successfully completed.
  • To prepare the specified PCIeSSD device for removal, run the following command:
    racadm storage preparetoremove: Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3
    STOR089 : Successfully accepted the storage configuration operation.
    To apply the configuration operation, create a configuration job with --realtime option.
    To create the required commit jobs, run the jobqueue command.
    For more information about the jobqueue command, enter the RACADM command "racadm help jobqueue”
    
  • To perform a secure erase operation on the specified PCIeSSD device, run the following command:
    racadm storage secureerase: Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3
    RAC1040 : Successfully accepted the storage configuration operation.
    To apply the configuration operation, create a configuration job, and then restart the server.
    To create the required commit and reboot jobs, run the jobqueue command.
    For more information about the jobqueue command, enter the RACADM command "racadm help jobqueue”
    
  • To cancel background initialization of a virtual disk

    racadm raid cancelbgi:Disk.Virtual.0:RAID.Integrated.1-1
    
  • To replace physical disk in a virtual disk configuration

      racadm raid replacephysicaldisk:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1 -dstpd Disk.Bay.1:Enclosure.Internal.0-0:RAID.Integrated.1-1
    
  • To set virtual disk as a boot drive

    racadm raid setbootvd:RAID.Integrated.1-1 -vd Disk.Virtual.0:RAID.Integrated.1-1
    
  • To set virtual disk as a boot drive

    racadm raid setbootvd:RAID.Integrated.1-1 -vd Disk.Virtual.0:RAID.Integrated.1-1
    
  • To force physical disk online or retrive data on physical/virtual disk

    racadm raid forceonline:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1
    
  • To force physical disk offline or remove disk from virtual disk configuration

    racadm raid forceoffline:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.1-1
    
  • To unlock storage
    racadm storage unlock:RAID.Integrated.1-1 -key 1234 -passwd Dell@333

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\