For C6320 - PowerEdge C6300 ENCLOSURE FCB FW Update.

AUTO INSTALLED This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This package contains the Fan Control Board FW update.
To view all drivers for your PowerEdge c6300, go to Drivers and downloads.
Recommended
Loading the latest available version of the driver...

This is the latest Dell validated version of this driver

This is not the latest Dell validated version of this driver

V0213-2017-08-22(heavy).exe | 208.56 KB
This is a large file. Depending on your connection speed, it may take some time to download.

File Format: Firmware Images
File Name: V0213-2017-08-22(heavy).exe
File Size: 208.56 KB
Format Description
To ensure the integrity of your download, please verify the checksum value.
MD5:
c567c24e0abad14c7d34e59efc0d92ec
SHA1:
a0cb4f09c1373304f76454a89f6ebc61a608a468
SHA-256:
2d9ca7755f7c6494376336d6a5a388488b2ec2130b14d679181e5a26da1a98cc

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Fixes
-None for this release.

Enhancements
-Add SEL in iDRAC for FCB thermal/power events.
-Set ADM1275 continuously sampling PSU current/voltage so FCB does not need to get PSU info periodically via I2C bus.
Read More

Version

2.13, A00-00

Release date

22 Mar 2018

Download Type

Firmware

Category

Device Firmware

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.

Additional details

Show All | Hide All
DCS6300
1. Run the self extracting file and rename the updating file from FC0213.bin to FC0213.sc.
2. Check iDRAC IP, connect and login iDRAC to enable IPMI over LAN under iDRAC Settings>Network>IPMI Settings.
3. Download RACADM and IPMI tools from Dell.com.
4. Execute the script "racadm -r xxx.xxx.xxx.xxx -u Username -p Password update -f FC0213.sc" to update FCB FW under the folder with RACADM tool included. Where xxx.xxx.xxx.xxx is the iDRAC IP, Username and Password is the login name and Password.
5. When updating the FCB FW by the RACADM, at least 20 minutes is required after seeing the message "RAC1066: Firmware update for FC0213.sc" initiated successfully.
6. Execute the script "ipmitool -I lanplus -H xxx.xxx.xxx.xxx -U Username -P Password raw 0x30 0x12" to check the FW version under the folder with IPMI tool included.
7. Please check ReleaseNote_V0213(heavy).txt for more details.