Dell EMC iDRAC Service Module 3.4 User’s Guide

Automatic System Recovery

Automatic System Recovery feature is a hardware-based timer, which is used to reset the server in the event of a hardware failure. You can perform automatic system recovery operations such as reboot, power cycle, or power off after a specified time interval. This feature is enabled only when the operating system watchdog timer is disabled. If OpenManage Server Administrator is installed, this monitoring feature is disabled to avoid duplicate watchdog timers.

You can configure three parameters in this feature from iDRAC interfaces:

  1. Watchdog state: The default state is enabled when OMSA is not present, and when BIOS or OS watchdog timer is disabled.
  2. Watchdog timeout: The default value is 480 seconds. The minimum value is 60 seconds and the maximum value is 720 seconds.
  3. Watchdog timeout Recovery Action or Auto Recovery Action: The actions can be Powercycle, Power Off, Reboot or None.